Sign In | Join Free | My frbiz.com
frbiz.com
Products
Search by Category
Home > Alarm >

30S Infrared Hydrocarbon Gas Detector Sensor 0-50000ppm

Categories Gas Detector Sensor
Brand Name: Kacise
Model Number: KSS574
Place of Origin: shanxi xi'an
MOQ: 1
Payment Terms: T/T, Western Union, MoneyGram
Supply Ability: 1000 Pieces per Week
Delivery Time: 5 work days
Packaging Details: each unit has indicidual box and all boxes are packed in standard packages or customers requests available
Storage Temperature: -20-80℃
Operating Temperature: -20-60℃
Operating Humidity: 0-90%RH
Work Pressure: 0.8-1.2 atm
Supply Voltage: 12V
Maximum Operating Current: 120mA
Detection Range (customizable).: 0-50000ppm
Resolution: 1000ppm
Measurement Accuracy: ± 50ppm or ±5% truth value is the greater %vol
T90 of Diffusion: 30S
Repeatability of Zero: Less than ±50ppm
Repeatability of Range: Less than ±5% of the measured value
Life Span: 10 years
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

30S Infrared Hydrocarbon Gas Detector Sensor 0-50000ppm

KSS574 Infrared Hydrocarbon Sensor


Table 1 Version history

versiondatedescription
V1.02016-10-12V1.0 released
V2.22018-03-06Adapt product attribute modifications

Table of Contents

1. Overview............................................................................................................. 4

2. Technical Parameters............................................................................................ 6

3. Structural Dimension Drawing................................................................................ 7

4. Installation instructions................................................................................................... 8

5. Matters that should be paid attention to in maintenance..................................................... 8

6. Ordering Instructions...................................................................................................... 9

7. Order Information......................................................................................................... 10

8. Contact Details............................................................................................................. 11


1. Overview

The KSS574 is a gas sensor based on the principle of NDIR infrared absorption, suitable for testing methane gas concentrations in industrial applications.

KSS574 adopts a patented optical cavity, imported light source and dual-channel detector to realize the reference compensation of dual optical paths in space. KSS574 has good selectivity, no oxygen dependence and long life.

KSS574 has a UART output mode, provides zero point calibration, sensitivity calibration and clean air calibration commands, and provides customers with a manually calibrated MCDL pin, which is convenient for customers to use outdoor free flow clean air to perform relative zero calibration of the sensor module.

The KSS574 adopts diffusion ventilation method and has a response time of less than 30 seconds. KSS574 is suitable for petrochemical power and other applications.

The KSS574 is available in a variety of packages that can be customized according to customer needs. There are three common packages: package one, package two (six pins 4-20mA), package three (seven pins 485 interfaces), of which package two and package three are the same size.


2. Technical Parameters


parametersymbolminimumTypical valuesmaximumunit
Storage TemperatureTstg-20-80°C
Operating TemperatureTA-2060°C
Operating HumidityHA090% RH
Work PressurePA0.81.2atm
Supply VoltageVs91218V
Maximum Operating CurrentIavg100120150mA
Detection Range (customizable).Ra050000ppm
ResolutionResolution1000ppm
Measurement AccuracyAcurracy± 50ppm or ±5% truth value is the greater%vol
T90 pipeline typediffusion30second
RepeatabilityZeroLess than ±50ppm
RangeLess than ±5% of the measured value
life span3510year

3. Structural Dimension Drawing

Unit: mm

Package a structural dimension drawing


Package 2 (6-pin 4-20mA).


Package three (seven-pin 485 connectors).


4. Installation instructions

The sensor mounting thread dimensions refer to the block diagram.

5. Matters that should be paid attention to in maintenance

The sensor should be calibrated regularly, it is recommended that it should not be more than 3 months;

Do not use the sensor for a long time in an environment with high dust density;

Please use the sensor within the range of the sensor's power supply.

6. Ordering Instructions

In order to be able to purchase the specific specifications required, please provide the following information

1) Sensor name

2) Sensor range

3) Sensor measurement accuracy and output mode, etc

For example, SW741, 0-50000ppm, ±5% of the reading or 50ppm whichever is the largest;


7. Order Information


Order information sheet
KSS574KSS574 CO2 concentration sensor
xxxxThe sensor measures the range of CO2 concentration in ppm, with a minimum value of 2000 and a maximum value of 50000 ppm.
2000Range 200ppm (default).
10000Range 10000ppm
50000Range 50000ppm
encodeThe reaction speed is divided into two types: fast and slow
SSlow (default).
Qfast
encodeBaud rate selection, support commonly used baud rate 2400 9600 19200 38400bps, 8 bits of data, 1 bit of stop bit, no check bit: Confirm special needs before ordering.
CustomConfirm the baud rate before ordering
24002400bps baud rate
96009600bps baud rate
1920019200bps baud rate
3840038400bps baud rate (default)
encodeSerial port protocol
Modbus-RTUStandard Modbus-RTU protocol (default).
Modbus-ASCIIStandard Modbus-ASCII protocol
Modbus-SelfModbus private protocol
KSS574-2000-S-38400-Modbus-RTU

8. Contact Details

URL: www.kacise.com

Tel: +86-29-17719566736

Email: sales@kacise.com

Address: Tangyan South Road, Xi'an City, Shaanxi Province, China


Appendix


ShorthandFull name
VOL1% VOL refers to 1% of the volume of a particular gas in air.
PPM1PPM means that the volume of a specific gas in the air accounts for one millionth.
O2Oxygen molecules
LCDLCD display
RS485Asynchronous serial port 485
DCdirect current
ACCommunication
PVCpolyvinyl chloride

Quality 30S Infrared Hydrocarbon Gas Detector Sensor 0-50000ppm for sale
Send your message to this supplier
 
*From:
*To: Xi'an Kacise Optronics Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0