Brand Name: RAINBOW
Model Number: PM-9000E
Certification: ISO13485, FSC
Place of Origin: Hunan, China
MOQ: 1 unit
Price: US $725-868/unit
Payment Terms: L/C, T/T, Western Union, MoneyGram
Supply Ability: 30000units/year
Delivery Time: Within 3 days
Packaging Details: Anti-collision film+ Carton box Packing size: 40X35X30cm Gross weight: 6.3 kg
Product Name: Maternal Fetal Monitor
Power Source: Electricity
Warranty: 1 Year
Material: Metal, Plastic
Display: 12.1 inch color TFT
Shelf Life: 2 years
Instrument classification: Class II
After-sale Service: Online technical support
OEM/ODM: Available
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

12.1 Inch Fetal FHR Monitor 9 Parameters Fetal Monitoring Machine 6.3kg

Comprehensive and Accurate Medical Apparatus 9 Parameters Toco FHR FM Maternal Fetal Monitor for Hospital


Basic information:

Nine parametersFHR, TOCO, FM, ECG,HR,SPO2,NIBP,RESP, TEMP
Size12.1 inch
Gross Weight6.3kg
Voltage220v
Power40w
Leads3-5 leads
Suitable placeshospital departments bedside care ward, ICU, CCU, operating theaters, prenatal care unit emergency centers, family care and the like.
Optionalmobile stand/wall mount
SFDA classificationClass II
Working systemContinuous running equipment

Features:

1.new high-precision modules, new digital oxygen technology

2.12" color TFT display, up to 12 waveforms

3.3 in 1 transducers, no cable inter twisting.
4.Arrhythmia analysis, ST calculation, Pace analysis

5.Various interfaces: A single guide, standard, large font, all leads
6.Anti-ESU, anti- defibrillator



Standard configuration:

PM-9000E maternal fetal monitor×1 set,

build-in dual channel thermal printer×1 set,

triple fetal probe×1 set,

ultrasound gel×1 bottom,

probe bandages×1 set,

standard 5-leads ECG conductance joint connecting cables×1 set,

standard adult blood pressure cuffs×1 set,

adult SPO2 probe×1 set,

TEMP probe×1 set,

power plug line×1 set,

grounding wire×1 set,

English operation manual×1 set.

Three certificates×1 set.

Optional:

Build-in rechargeable lithium battery; monitor mobile stand/ cart.


Technical Parameters

FHR

Probe: Nine wafer, wide beam, pulsed operation mode and high sensitivity.

Ultrasound intensity: less than 1mW / cm²

Operating frequency: 1.0MHz

Signal Processing: dedicated digital signal processing unit

Maximum Audio Output Power: 1.5W

TOCO


10-100 pressure unit


Ultrasonic Probe Output


In accordance with the provisions of the international convention in 1992, IEC1157, negative peak sound pressure of not more than l trillion Pa (MPa). Beam sound intensity does not exceed 20 mW / cm 2 (mW / cm ²). Sound intensity spatial peak temporal average density of less than 100 mW / cm (mW / cm ²). The models sound intensity does not exceed 1mw / cm ²

Coupling Agent (GEL)


Viscous water-based sets of objects. On the skin without stimulation, no allergies. Chemically stable, inhibit bacterial type.


ECG

lead mode;I,II,III,AVR,AVL,AVF,V1-6

Gain: ×0.25, × 0. 5, and × 1, × 2

Frequency: 0.5 Hz - 100 Hz

Common-mode signal inhibition: More than 70 dB

Scan rate: 12.5 mm / S, 25 mm / S, 50 mm / S standard three stalls.

HR: ± 5 BPM

Precision calibration signal: 1mv(peak, ± 3% accuracy)

ST Detection: measurement range (-2.0mV----+2.0mV)

Using Standard: meet the ANSI / AMI EC13 -2002 standard

Response time: 1s

Alarm: Sound and Light

Preset heart rate range: (Alarm over preset numerical)

Ceiling: 1-255 bpm adjustable

Threshold: 0-254 bpm adjustable

NIBP

Technology: Oscillography

Mode: manual / automatic

Measurement units: mmHg / kPa

Scope: Pressure Cuffs 0-250 mmHg

Inflatable cuffs: 180 mmHg (120mmHg for children, 70mmHg for newborn)

Inflatable cuffs follow: original SBP: + 30 mmHg

Measuring range: SYS: 60-250 mmHg

DIA: 40-220 mmHg

MEAN: 45-235 mmHg

Response time: 1s

Alarm: Sound and Light

Preset range: report (Numerical exceed preset alarm)

SYS: maximum: 1-255 mmHg adjustable

Threshold: 0-254 mmHg adjustable

DIA: ceiling: 1 -255 mmHg adjustable

Minimum standards: 0-254mmHg adjustable

SPO2

Range: 0-100%

Accuracy: 1%

Resolution: 1%

Pulse frequency: 20-250 times / min

Response time: 1s

Alarm: Sound and Light

Preset range: (report Alarm over preset numerical)

Ceiling: 1% - 100% adjustable

Threshold: 0% - 99% adjustable

TEMP

Technology: thermostat temperature probe

Measuring range: 20 ° C-45 ° C

Temperature resolution: 0.1%

Accuracy: ± 0.1 ° C

Response Time: 1s

Alarm: Sound and Light

Preset range: report (numerical preset alarm over)

Maximum: 20.1 ° C-45.5 ° C adjustable

Threshold: 20 ° C-45.4 ° C Adjustable

RESP

Breathing frequency range: 0-60 bum

Accuracy: ± 1rpm

Response time: 1s

Gains options: × 1, × 2, × 0.5, and × 0.25 four trenches

Alarm: Sound and Light

Alarm range: (numerical preset alarm over)

Ceiling: 10-100 bpm adjustable

Threshold: 0 -99 bpm adjustable

Printer(Optional)


Specification: Dual channel thermal array data recorder

Print mode: Real time or event triggered record waveform and text

Accuracy: horizontal: 4oodpi vertical: 800dpi

Annotation: Date/ time(24 hours)

Optional wall bracket, mobile stand, visits backpack.

System

Screen:12.1 inches TFT screen of LCD

Battery: sealed maintenance-free lithium battery

Safety standard: lec601-1(GB9706.1)


ECG

lead mode;I,II,III,AVR,AVL,AVF,V1-6

Gain: ×0.25, × 0. 5, and × 1, × 2

Frequency: 0.5 Hz - 100 Hz

Common-mode signal inhibition: More than 70 dB

Scan rate: 12.5 mm / S, 25 mm / S, 50 mm / S standard three stalls.

HR: ± 5 BPM

Precision calibration signal: 1mv(peak, ± 3% accuracy)

ST Detection: measurement range (-2.0mV----+2.0mV)

Using Standard: meet the ANSI / AMI EC13 -2002 standard

Response time: 1s

Alarm: Sound and Light

Preset heart rate range: (Alarm over preset numerical)

Ceiling: 1-255 bpm adjustable

Threshold: 0-254 bpm adjustable

NIBP

Technology: Oscillography

Mode: manual / automatic

Measurement units: mmHg / kPa

Scope: Pressure Cuffs 0-250 mmHg

Inflatable cuffs: 180 mmHg (120mmHg for children, 70mmHg for newborn)

Inflatable cuffs follow: original SBP: + 30 mmHg

Measuring range: SYS: 60-250 mmHg

DIA: 40-220 mmHg

MEAN: 45-235 mmHg

Response time: 1s

Alarm: Sound and Light

Preset range: report (Numerical exceed preset alarm)

SYS: maximum: 1-255 mmHg adjustable

Threshold: 0-254 mmHg adjustable

DIA: ceiling: 1 -255 mmHg adjustable

Minimum standards: 0-254mmHg adjustable

SPO2

Range: 0-100%

Accuracy: 1%

Resolution: 1%

Pulse frequency: 20-250 times / min

Response time: 1s

Alarm: Sound and Light

Preset range: (report Alarm over preset numerical)

Ceiling: 1% - 100% adjustable

Threshold: 0% - 99% adjustable

TEMP

Technology: thermostat temperature probe

Measuring range: 20 ° C-45 ° C

Temperature resolution: 0.1%

Accuracy: ± 0.1 ° C

Response Time: 1s

Alarm: Sound and Light

Preset range: report (numerical preset alarm over)

Maximum: 20.1 ° C-45.5 ° C adjustable

Threshold: 20 ° C-45.4 ° C Adjustable

RESP

Breathing frequency range: 0-60 bum

Accuracy: ± 1rpm

Response time: 1s

Gains options: × 1, × 2, × 0.5, and × 0.25 four trenches

Alarm: Sound and Light

Alarm range: (numerical preset alarm over)

Ceiling: 10-100 bpm adjustable

Threshold: 0 -99 bpm adjustable

Printer(Optional)


Specification: Dual channel thermal array data recorder

Print mode: Real time or event triggered record waveform and text

Accuracy: horizontal: 4oodpi vertical: 800dpi

Annotation: Date/ time(24 hours)

Optional wall bracket, mobile stand, visits backpack.

System

Screen:12.1 inches TFT screen of LCD

Battery: sealed maintenance-free lithium battery

Safety standard: lec601-1(GB9706.1)

FAQ

Q1.Are you a factory?
Yes, we are,welcome to visit our company and factory
Q2.Do you have MOQ limited?
NO, we don't have
Q3.Can you accept OEM ODM service?
Yes, we can
Q4.What is the shipping way?
DHL/FEDEX/UPS/TNT/EMS,it's up to you
Q5.What is the delivery date of my order?
2 or 3 days for sample orders, 5-10 days for wholesale order after we received the payment
Q6.When can I receive the goods?
3-7 days by express delivery.

Quality 12.1 Inch Fetal FHR Monitor 9 Parameters Fetal Monitoring Machine 6.3kg for sale
Send your message to this supplier
 
*From:
*To: Hunan Province Rainbow Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0