Categories | Disinfectant Analyzer |
---|---|
Brand Name: | Daruifuno |
Model Number: | CD4.2 |
Certification: | CE |
Place of Origin: | China |
MOQ: | Negotiable |
Price: | Negotiable |
Product Name: | Chlorine Dioxide Sensor |
Product Model: | Chlorine Dioxide Sensor CD4.2 |
Indicator: | Chlorine Dioxide |
Temperature Range: | 0 ~ 45℃ |
PH Range: | 1 ~ 12 |
Pressure Range: | 0 ~ 1bar, no pressure surges or fluctuations |
Response Time: | T90 15sec. |
Flow Rate: | 30L / h, low flow-dependence |
Run-in Time: | First start-up about 1 h |
Material: | PVC-U, semipermeable membrane |
Company Info. |
Suzhou Delfino Environmental Technology Co., Ltd. |
Verified Supplier |
View Contact Details |
Product List |
2 Electrode Chlorine Dioxide Sensor Membrane Covered Water Quality Probe
Descriptions
The chlorine dioxide sensor CD4.2 is for the measurement of chlorine dioxide. The water quality probe is Membrane-covered, amperometric 2-electrode system. The measurands of the chlorine dioxide sensor water quality probe is chlorine dioxide.
If you want to calibrate the sensor, at the controller, via analytical chlorine-dioxide determination by DPD-1 method. The material of the sensor is PVC-U, semipermeable membrane. The Pressure range of the chlorine dioxide sensor is 0 ~ 1bar. The measuring water temperature is from 0℃ to 45℃. No ice crystal is allowed in the measuring water. The flow rate of the chlorine dioxide sensor water quality probe is about 15 ~ 30L/h, small flow rate dependence is given.
Specifications
Product Name | Chlorine Dioxide Sensor Water Quality Probe |
Product Model | Chlorine Dioxide Sensor CD4.2 |
Measuring System | Membrane Covered, amperometric 2-electrode system |
pH Range | 1~12 |
Pressure Range | 0~1bar |
Temperature Range | 0~45℃ |
Flow Rate | 30 l/h low flow-dependence |
Response Time | T90 15sec. |
Connection | mA - version 2-pole terminal, M12 male or Modbus RTU with M12 male |
Shaft Length | standard 175 mm, and up to 220 mm in length (mA - Version) |
Zero Point Adjustment | Not necessary |
Applications Of The Chlorine Dioxide Sensor
Scope Of Supply
Water quality probe chlorine dioxide sensor CD4.2: sensor, membrane cap, electrolyte.
Ordering Data:
Type | Measuring range(ppm) | Resolution(ppm) | Output signal | Power supply | Item number |
CD4.2H-M0c | 0.005~2.000 | 0.001 | Modbus RTU | 9~30 V DC | 3326465 |
CD4.2N-M0c | 0.05~20.00 | 0.01 | 3326466 | ||
CD4.2MA0.5 | 0.005~0.500 | 0.001 | 4~20 mA | 12~30 VDC | 3326480 |
CD4.2MA2 | 0.05~2.00 | 0.01 | 3326481 | ||
CD4.2MA5 | 0.05~5.00 | 0.01 | 3326482 | ||
CD4.2MA10 | 0.05~10.00 | 0.01 | 3326483 | ||
CD4.2MA0.5-M12 | 0.005~0.500 | 0.001 | 4~20 mA | 12~30 VDC | 3326490 |
CD4.2MA2-M12 | 0.05~2.00 | 0.01 | 3326491 | ||
CD4.2MA5-M12 | 0.05~5.00 | 0.01 | 3326492 | ||
CD4.2MA10-M12 | 0.05~10.00 | 0.01 | 3326493 |