Overhead ACSR Conductors In Transmission Lines With Code: 800/900/1000/1120/1250(AAC,AAAC,ACSR)
...Conductor Wire(Area AL:160mm2 Steel:8.89mm2 Total:169mm2), ACSR Conductor according to IEC 61089 Overhead ACSR Conductors APPLICATION ACSR conductors are widely used for electrical power transmission over long distances, since they are ideal for long overhead lines spans. They are also used as a messenger for supporting overhead electrical cables. Overhead ACSR Conductors......
Zhenglan Cable Technology Co., Ltd
|
Superior Bare Cable ACSR Conductor Aluminum Conductor Steel Reinforced For Overhead
...ACSR Conductor Aluminum Conductor Steel Reinforced For Overhead Product Name Overhead Conductor ACSR Aluminium Conductor Steel Reinforced (ACSR) Conductor Aluminum Construction Aluminum Stranded & Steel Reinforce Colors Assorted upon request Voltage 600-1000V, 1KV-35KV Application Used as bare overhead conductor for power distribution lines Standards GB/T 1179, IEC 60889, IEC 61089,BS,DIN and ICEA upon request Description ACSR...
Luoyang Sanwu Cable Co., Ltd.,
|
High Tensile Strength 1x2 Galvanized Steel Wire Strand For ACSR Conductor
High tensile strength Galvanized steel wire strand for ACSR Conductor Application: Being used for electric cables,telephone cables,ACSR Conductor,overhead transmission line etc Characteristic:High tensile strength,good wear resistance and uniform diameter ......
Nanjing Suntay Steel Co.,Ltd
|
Overhead Bare Aluminum Conductor Steel Reinforced Strands For ACSR Conductor
... drawn 1350-H19 aluminium wire on galvanized steel wire core. The core can be single wire or stranded depending on the size. Steel core wire is available in Class A , B or Class C galvanization for corrosion protection. Additional corrosion protection is...
Ningbo Suntech Power Machinery Tools Co.,Ltd.
|
ACSR Conductor Aluminium Alloy Conductors For Overhead Transmission Line BS215
...aluminum wire, and grease if necessary. Application: Conductor (AAC and ACSR) have been widely used in power transmission lines with various voltage, because they have such good characteristics as simple structure, convenient installation and maintenance,...
Shanghai Shenghua Cable (Group) Co., Ltd.
|
Overhead ACSR Conductor Stranded LV MV HV Electrical Power Transmission
Aluminum AAC AAAC Hard Drawn Standard Bare Steel Reinforced Overhead ACSR Conductor ACSR bare stranded aluminum conductor Description: (1) Brief Description ACSR conductor consists of a solid or stranded steel core surrounded by strands of aluminium (E.C.......
Zhejiang CHINT Cable Co., Ltd
|
DIN 48204 Aluminium Conductor Steel Reinforced Cable , ACSR Conductor Bare Insulation
...Conductor Steel Reinforced Cable , ACSR Conductor Bare Insulation ACSR Conductor Introduction ACSR CONDUCTOR is available in a wide range of steel varying from as low as 6% to as high as 40 %. The higher strength ACSR CONDUCTORS are used for river crossings, overhead ground wires, installations involving extra long spans etc.. Against any given resistance of conductor, ACSR CONDUCTORS......
Shenzhen Chengtiantai Cable Industry Development Co.,Ltd
|
10KN ACSR Large Diameter Rope Pulley ACSR Conductor Single Sheave Stringing Block
...tangent structures in overhead transmission line. Application: Widely used in overhead power line construction. Used to release conductors. It can be passed byconnectors, swivel joints. A block and tackle system which combined with many pulleys is often...
SUZHOU SHENHONG IMPORT AND EXPORT CO.,LTD
|
High Voltage Twin Moose Conductor , Acsr Conductor For Power Transmission Line
...Conductor Aluminium Alloy 6201 Used in Power Transimission Line Application AAAC conductors are designed to get better strength to weight ratio and offer improved electrical properties, excellent sag-tension characteristics, and superior corrosion resistance when compared with ACSR. As compared to a conventional ACSR conductor......
Qingdao Yilan Cable Co., Ltd.
|
Efficient Conductive ACSR Conductor 4.72mm Electric Power Cable Zn 5A1 MM
... and distribution projects. - Excellent weather-resistance property. - Dependable and stable performance up to 40 years. Construction of bare ACSR conductor - Concentric-lay stranded - 1 up to 4 Layers Aluminum wires stranded, 6 to 84 Aluminum wires....
Beijing Cable Industry Development Co.,Ltd
|