DEKON VRF air conditioner X series DC inverter Out door units modular type 14HP 40KW under T3 conditions

Categories VRF Air conditioner
Brand Name: DEKON or OEM
Model Number: DRV140AX
Certification: CE, ISO,AHRI
Place of Origin: made in china
Price: TBC
Payment Terms: TT
Supply Ability: 200PCS PER MONTH
Delivery Time: 30days after payment
Packaging Details: Standare Export packing
MOQ: TBC
Use: Room
Power Source: Electrical
Type: Central Air Conditioners
Cooling/Heating: Cooling/Heating
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    DEKON VRF air conditioner X series DC inverter Out door units modular type 14HP 40KW under T3 conditions

    DEKON VRF air conditioner X series DC inverter Out door units modular type under T3 conditions


    Below is the introduction of Modular type Out door units:


    DEKON VRF air conditioner X series Full DC Inverter technology

    DC inverter Hitachi compressor

    Working temperature from -5 to 52 degrees, T3 conditions

    2 pipe system now, and 3 pipes system coming soon.

    Modular design, can be max 3 module connected together.

    Single module: 8/10/12/14/16/20/22HP

    Combination Module: 24HQ up to 66HP


    Cooling capacity 40kw/14HP

    Model No. DRV140AX



    DEKON DRV X series specifications:


    Dekon ModelDRV080AXDRV100AXDRV120AXDRV140AXDRV160AXDRV180AXDRV200AXDRV220AX
    Combination model--------
    CapacityCapacity rangeHP810121416182022
    CoolingkW252833.54045505661.5
    HeatingkW2731.537.54550566369
    Power supplyV/N/Hz380V/3N/50Hz/60Hz
    EERkW/kW4.083.953.883.753.563.533.63.68
    COPkW/kW4.454.494.364.253.993.964.064.14
    Rated inputCoolingkW6.127.098.6310.6712.6414.1615.5616.71
    HeatingkW6.077.028.610.5812.614.1215.5216.65
    RatedCoolingA12.513.416.419.624.130.535.240
    currentHeatingA13.613.916.7202430.134.935
    RefrigerantTypeR410A 
    Charge volumekg8101216
    CompressorBrandHitachi
    TypeScroll type
    Quantity11+1
    Refrigerant oilL0.51.10.50.5
    charge volume
    FanType Axial flow
    Quantity 11+1
    Fan motorInsulation classIP24
    Drive TypeDC
    Airflow ratem3/h1200013980187802082022020
    Connecting pipeLiquid pipemmφ12.7φ12.7φ12.7φ15.88
    Gas pipemmφ22.23φ25.4φ28.58φ28.58
    Connection methodWelding
    ESPPa0-80
    Sound pressure leveldB(A)45-5745-5945-6245-63
    Outline dimensionmm930*860*17101240*860*17101500*860*17101500*860*1710
    Package dimensionmm930*860*20001240*860*20001500*860*20001500*860*2000
    Net weightkg225225225290290430430430
    Gross weightkg245245245310310450450450
    Maximum drive IDU NO.unit1416192223313334
    Max. equivalent connectionm240240240240240240240240
    pipe length
    Working temp.Cooling°C-5-52°C
    Heating°C-20-24°C

    DEKON VRF air conditioner-China Professional VRF supplier/factory for many years.

    We have exported DEKON DRV Air conditioner to more than 20 different countries.

    If need selection or designing for your project, pls contact us directly by mail.

    Or scan below code on the picture shown.



    Our designed project for Bolivia project.



    Below is the detailed introduction for DEKON VRF System control ways:



    Brief introduction about DEKON VRF System.


    1. Environmental and healthy


    A. DC inverter module uses of R410A refrigerant, non destruction to the ozone layer, energy saving, environmental protection and pollution-free;
    B. All materials of DC inverter module comply with RoHS environmental directive.


    2. Reliable and durable
    Adopted Hitachi compressors, efficient, reliable, frequency and fully verified.


    3. High efficiency and energy saving
    A. DC inverter module uses Hitachi compressor high-performance high efficiency ;
    B. DC inverter module uses advanced output capacity control technology, according to the indoor, outdoor temperature and load of indoor unit, automaticallyadjust system output capacity, so that indoor can remain in a stable and comfortable temperature, reaching high efficiency and energy saving effect;
    C. In cooling mode, EER can achieve up to 4.18, with average EER 3.55;
    D. In heating mode, COP can achieve up to 4.37, with average COP 3.96;


    4. Long piping design
    Maximum length of pipeline up to 150 meters, the max.
    Height difference between indoor and outdoor unit up to 50 meters, widely use;


    5. Wide operation temperatureCooling operation temperature: -5 ~ 50 degrees
    Heating operation temperature: -15 ~ 28 degrees


    6. Intelligent control
    Our VRF unit only uses one set of control software can manage up to 4096 sets indoor units, canculating each indoor unit as 5HP, total management over 20, 000HP.


    For more info, please mail us directly to info@dekon-china.com.

    Or add whatsapp 0086-15356475680/Simon

    Quality DEKON VRF air conditioner X series DC inverter Out door units modular type 14HP 40KW under  T3 conditions for sale
    Send your message to this supplier
     
    *From:
    *To: Ningbo Dekon New Energy Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0

    Friendly Links: www.everychina.com

    Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Help

    Copyright © 2009 - 2024 frbiz.com. All rights reserved.