    Fire Alarm Control Panel (Linkage Type) CJ-9000-2 Intelligent Fire Alarm Panel 2 loops,each loop for 324 addresses

    Fire Alarm Control Panel (Linkage Type) CJ-9000-2 Intelligent Fire Alarm Panel 2 loops,each loop for 324 addresses

    The fire alarm control panel has a modular design and is characterized by great functions, large capacity, flexible configurations and an excellent price-performance ratio. The system has a large screen supporting Chinese display and a standard special miniprinter that can print all the alarms, faults and operations of the system into Chinese. The system can realize comprehensive on-site programming and solve complicated linkage relation settings. The system simulates the operating interfaces of Windows and is therefore easy to learn, use and realize Chinese input.
    Each fire alarm control panel has a maximum capacity of 25,920 bus alarm linkage control points.

    System characteristics

    It adopts new generation high-speed microprocessor technology that has a data processing speed and a data storage capacity 100 times and 1000 times higher than that of conventional technology respectively.
    It has a 7.4″16-grey-scale LCD Chinese-supporting display and with a display resolution of 640*480.
    Its operating interfaces simulate the menus and interfaces of Windows and therefore ensure operation habits similar to that of computers and is easy to learn.
    It uses a flexibly and conveniently controllable standard PS/2 computer keyboard and mouse as on-site programming devices.
    It provides a Chinese Pinyin input method and a Chinese section-position code input method and can therefore realize Chinese input freely and easily.
    It can copy or restore both setting files and historical files through a CF intelligent storage card (optional), making system maintenance convenient.
    It adopts a non-polarity two-bus intelligent alarm linkage mode and has a total of 324
    intelligent detectors or modules for a single circuit. The addresses of the intelligent detectors or modules may be hashed with No.1 to No.324.
    It is equipped with multiple high-speed CAN-bus interfaces, ensuring quick and reliable data transmission.
    It has super high single-machine capacity (maximum single-machine capacity:
    40*2*324=25,920 alarm points).
    It supports the networking of 20 fire alarm control panels. It has a maximum capacity of 518,400 alarm points (20*25,920) after networking.
    It can be connected with a multi-line linkage control unit and has a maximum capacity of 4,000 points for a standalone linkage control unit.
    It can store the historical information of system operation, including 1,000 pieces of historical fire alarm information, historical request information, historical feedback information, historical fault information and historical operation information respectively.
    Users can customize the equipment type, making system integration convenient.
    It introduces the concept of a virtual interface board to realize the linkage operations of
    general semantics, thus realizing the most complicated system linkage relations easily.
    It has manual single-point start and stop functions for modules, making on-site debugging and tests convenient.
    It has a single-point test function for detectors or modules, making the operating conditions and test data of detectors intuitive.
    It has a standard special miniprinter, enabling it to print various operating conditions in a real-time way.
    It can be accessed to a zone display panel, a building display panel or a floor display panel to send the information displayed on it to locations like corridors.
    It can be connected with the 9000 graphical display device (optional, 9000 for short) in the fire control room to display the specific locations of fires and faults intuitively.
    It executes administration by different levels for users of multiple levels and grants the users at different levels the corresponding system operation authorities, making system administration convenient.
    It can realize local or remote software upgrades, thus enabling it to operate stably and
    reliably.
    Executive standards: Fire Alarm Control Units (GB4717-2005)
    Automatic Control System for Fire Protection (GB16806-2006)


    Technical parameters of the products of the system
    Power supplies:

    Main power supply: AC 220V+-20%/50Hz or DC24V
    Emergency power supply: Maintenance-free DC24V battery (its capacity depends on the system size).
    Operating conditions:
    Ambient temperature: -10DC~+55DC during system operation
    Ambient humidity: <=95% (40DC+-2DC, without condensation)
    Peripheral equipment:
    For the specific technical parameters of equipment like detectors, modules and audible
    and visual alarms, see the corresponding instruction manuals.

    Appearance and Dimensions

    Quality Fire Alarm Control Panel (Linkage Type) CJ-9000-2 Intelligent Fire Alarm Panel 2 loops,each loop for 324 addresses for sale
    Send your message to this supplier
     
    From:
    To: CJ E-TECHNOLOGY LTD
    Subject:
    Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0

    Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

    Copyright © 2009 - 2019 frbiz.com. All rights reserved.